This is an installation guide that describes the options and suitability of the Rinnai INFINITY® gas hot water heater internal flueing
This guide provides installation instructions for the internal flueing components of Rinnai INFINITY gas hot water heaters. It covers suitability for current models (EFi250 and HDi200) and discontinued models (HD200i, HDi200, HD200ia, XR26i, XR26ia). The document details various flueing configurations including direct flueing through external walls, horizontal extensions, vertical straight flueing through roofs, and combination flueing.
| Maximum wall thickness (EFi250) | 430 mm |
|---|---|
| Maximum wall thickness (HDi200) | 485 mm |
| Maximum total flue length (Horizontal) | 13 m |
| Maximum total flue length (Vertical) | 15 m |
| Condensate trap requirement (HDi200) | Flue lengths over 1.5 m |
| Condensate trap requirement (EFi250) | Not needed |
| Flue pipe slope | 20 mm per metre |
A condensate trap kit (FFSSCOND) is required for HDi200 units when the flue length exceeds 1.5 meters.
No, the FFSSCOND is not needed for the EFi250 as it uses a different method for draining condensate.
The maximum wall thickness is 430 mm for the EFi250 and 485 mm for the HDi200.