This manual contains the installation instructions for the Rinnai R85 tankless water heater, including safety precautions and clearance distances.
This document provides installation instructions for the Rinnai R85 tankless water heater. It includes safety warnings, minimum clearances from combustible materials, vent terminal positioning, and gas pressure settings. The unit must be installed by an authorized person and requires specific vent pipe slope and condensation drainage provisions. Gas type switches must be correctly set for natural gas or propane.
Commissioning checks ensure proper gas pressure, with specified ranges for natural gas and propane. The regulator is factory pre-set and should not be adjusted unless the unit is not operating correctly after checking other causes.
| Minimum Clearance - Top | 6 inches |
|---|---|
| Minimum Clearance - Back | 0 inch |
| Minimum Clearance - Front | 6 inches |
| Minimum Clearance - Sides | 2 inches |
| Minimum Clearance - Floor | 12 inches |
The document does not provide instructions on resetting the unit.
The document mentions a 'COLD water inlet filter inlet' but does not specify its location.
Dip switch 1 of SW2: 'ON' = Natural Gas, 'OFF' = Propane Gas.