Instructions-Parts NXT® Air Motor TI8621a With Linear Sensor Standard With DataTrak™
This manual provides instructions for the Graco TI8621a NXT Air Motor, which is designed for use with high-performance finishing and coating pumps. It covers the motor's identification, component identification, and operational modes including Setup and Run modes for the integrated DataTrak system. The document details the motor's specifications, such as a maximum working pressure of 100 psi, and includes safety warnings regarding fire, skin injection, and pressurized equipment hazards.
| Maximum Working Pressure | 100 psi (0.7 MPa, 7.0 bar) |
|---|---|
| Intended Use | High performance finishing and coating pumps |
| Usage Restriction | Professional use only |
The maximum working pressure is 100 psi (0.7 MPa, 7.0 bar).
High-pressure fluid can pierce skin, which may result in amputation and requires immediate surgical treatment.
The De-icing Control is used to reduce icing by opening it to allow warm feed air bleed.