Gilson 215 Liquid Handler User's Guide

Introduced the use and precautions of Gilson 215 liquid handler


Gilson 215 Liquid Handler User's Guide - cover page
Brand
Gilson
Document type
User Manual
Language
English
Pages
155
File format
PDF
File size
5.3 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
428FBB3F25C2E2EE5F947BC08F8389ED

About this manual

This guide provides step-by-step instructions for installing, operating, and maintaining the Gilson 215 Liquid Handler. It includes safety guidelines, setup procedures, maintenance tips, and troubleshooting for common issues. The manual also covers technical specifications, software utilities, and replacement parts.

The device is designed for laboratory use by trained personnel and complies with UL, CSA, and CE safety standards. It supports RS-232 and GSIOC communication, and features a programmable interface for automated liquid handling tasks.

What's inside

  • Safety
  • Installation
  • Operation
  • Maintenance
  • Troubleshooting
  • Replacement Parts
  • Technical Specifications
  • GSIOC Utility

Specifications

Arm Speed>45.7 cm/sec (>18 in/sec) in X dimension, >40.6 cm/sec (>16 in/sec) in Y dimension
Communication InterfaceRS-232 or GSIOC; Four inputs (contact closure, TTL, or open-collector), four relay outputs, and one switched +24V DC 1A output
Dimensions91 x 61 x 56cm (36 x 24 x 22 in)* *Maximum height. Z-arm height is adjustable to accommodate vessel heights between 1 and 150 mm (dependent on installed Z-arm)
Display Panel8-character display
Environmental ConditionsIndoor use, Altitude: up to 2000 m, Temperature range: 5°–40°C, Air pressure: 75–105 kPa, Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
Power RequirementsFrequency: 50/60 HZ, Voltage: 100–120 V or 220–240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage, Current rating: 2.0A for 100–120 or 1.0A for 220–240V
Probe Positioning PerformanceAccuracy: ±0.5 mm in X/Y dimensions ±1 mm in Z dimension, Repeatability: ±0.25 mm in X/Y/Z dimension
Reproducibility Liquid Handling1.37% CV with 50 μL of water, Injection <0.9% CV with 1 mL syringe and total loop filling method
Safety Approvals/ EMC ComplianceCertified to UL, CSA, CE, and C-Tick Safety/EMC standards

Frequently asked questions

What safety precautions should I follow when using the 215 Liquid Handler?

Keep hands clear of the probe to avoid piercing, use only specified fuses, ground the device, and follow all safety warnings in the manual.

What communication interfaces does the 215 Liquid Handler support?

It supports RS-232 and GSIOC interfaces, with four inputs and four relay outputs.

What is the maximum height of the 215 Liquid Handler?

The maximum height is 56 cm (22 in), with adjustable Z-arm height for vessel heights between 1 and 150 mm.

What is the environmental operating range for the 215 Liquid Handler?

It operates indoors with temperature range 5°–40°C, humidity up to 80% at 31°C, and altitude up to 2000 m.