Solvent Flush Kits User's manual, for use with Fusion and Fusion CS Spray Guns
The Graco Solvent Flush Kit is for use with Fusion and Fusion CS Spray Guns, which are not included. The manual lists models 248139 and 256510 and model 248229, and it covers setup, operation, pressure relief, parts, and technical data.
Safety instructions include warnings about toxic fluids or fumes, skin injection hazards, fire and explosion hazards, and protective equipment. The manual states the kit is for professional use only and refers to grounding and fluid manufacturer warnings.
| Maximum Fluid Working Pressure | Model 248139: 120 psi (0.8 MPa, 8.0 bar); Model 248229: 100 psi (0.7 MPa, 7.0 bar); Model 256510: 100 psi (0.7 MPa, 7.0 bar) |
|---|---|
| Maximum Air Operating Pressure | Model 248139: 120 psi (0.8 MPa, 8.0 bar); Model 248229: 100 psi (0.7 MPa, 7.0 bar); Model 256510: 100 psi (0.7 MPa, 7.0 bar) |
| Wetted Parts | Model 248139: carbon steel, aluminum, brass; Models 248229 and 256510: carbon steel, stainless steel, aluminum, nylon, acetal, PTFE, polypropylene, polyethylene |
The maximum fluid working pressure is 120 psi for model 248139 and 100 psi for models 248229 and 256510.
The operator must wear appropriate protective equipment, including protective eyewear, clothing and respirator, gloves, and hearing protection.
Pressure should be relieved before cleaning or repairing the gun, and the manual provides pressure relief procedures.