This document is the installation and maintenance manual for Hisense air conditioner, containing the use instructions and maintenance methods of the air conditioner
This Installation & Maintenance Manual covers Hisense inverter-driven multi-split heat pump air conditioners and their outdoor units. The document provides safety instructions and procedures for installation, refrigerant piping, electrical wiring, additional refrigerant charge, test run, and safety and control device settings.
It lists outdoor unit model ranges from AVWT-86U6SR to AVWT-460U6SZ and states operating temperature limits for cooling and heating. The manual also covers transportation and handling, service space, foundation, drain water treatment, and checking the product received.
| Refrigerant | R410A |
|---|---|
| Cooling indoor temperature range | 21 DB/15 WB to 32 DB/23 WB |
| Cooling outdoor temperature range | -5 DB to 43 DB |
| Heating indoor temperature range | 15 DB to 27 DB |
| Heating outdoor temperature range | -20 WB to 15 WB |
The manual specifies R410A refrigerant for the outdoor unit.
The outdoor cooling range is -5 DB to 43 DB.
Install the unit at least 3 meters away from electromagnetic wave sources such as a radio.