GBL 7500 Cartridge Lubricator Operation Manual

This manual introduces the features and usage instructions of GBL 7500 cartridge lubricators and shaft rotation/low level alarm pumps.


GBL 7500 Cartridge Lubricator Operation Manual - cover page
Brand
GBL
Category
Industrial Robot
Document type
User Manual
Language
Chinese
Pages
18
File format
PDF
File size
1.1 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
A777ED4E6A4B318C4C356472CA4A008E

About this manual

This manual provides instructions for the GBL 7500 cartridge lubricator and alarm pumps, which are designed for professional use to deliver low-flow mineral or synthetic oils to machinery. The document covers various pump configurations, including suction, gravity, pressure feed, and alarm models, detailing their specific operating pressures and applications. This manual is written in Chinese.

What's inside

  • Safety Warnings
  • Installation
  • Grounding
  • Priming the Pump
  • Connecting Lubrication Lines
  • Adjusting Pump Output
  • Alarm Pump Setup

Specifications

Maximum Operating Pressure (3/16 in.)7500 psi (51.7 MPa, 517 bar)
Maximum Operating Pressure (1/4 in.)6000 psi (41.4 MPa, 414 bar)
Maximum Operating Pressure (3/8 in.)3500 psi (24.1 MPa, 241 bar)
Maximum Operating Pressure (Alarm Pump)500 psi (3.4 MPa, 34.4 bar)
Maximum Allowable Inlet Pressure (Pressure Feed)100 psi (0.69 MPa, 6.9 bar)
Minimum Inlet Pressure (Pressure Feed)1 psi (0.007 MPa, 0.07 bar)

Frequently asked questions

What is the maximum operating pressure for the 3/16 inch model?

The maximum operating pressure for the 3/16 inch model is 7500 psi (51.7 MPa, 517 bar).

What is the recommended pressure setting for the alarm pump switch?

The pressure switch should be set to 50 psi (3.4 bar, 0.34 MPa) to trigger the alarm.

What is the maximum allowable inlet pressure for a pressure feed pump?

The maximum allowable inlet pressure for a pressure feed pump is 100 psi (0.69 MPa, 6.9 bar).