This manual introduces the features and usage instructions of GBL 7500 cartridge lubricators and shaft rotation/low level alarm pumps.
This manual provides instructions for the GBL 7500 cartridge lubricator and alarm pumps, which are designed for professional use to deliver low-flow mineral or synthetic oils to machinery. The document covers various pump configurations, including suction, gravity, pressure feed, and alarm models, detailing their specific operating pressures and applications. This manual is written in Chinese.
| Maximum Operating Pressure (3/16 in.) | 7500 psi (51.7 MPa, 517 bar) |
|---|---|
| Maximum Operating Pressure (1/4 in.) | 6000 psi (41.4 MPa, 414 bar) |
| Maximum Operating Pressure (3/8 in.) | 3500 psi (24.1 MPa, 241 bar) |
| Maximum Operating Pressure (Alarm Pump) | 500 psi (3.4 MPa, 34.4 bar) |
| Maximum Allowable Inlet Pressure (Pressure Feed) | 100 psi (0.69 MPa, 6.9 bar) |
| Minimum Inlet Pressure (Pressure Feed) | 1 psi (0.007 MPa, 0.07 bar) |
The maximum operating pressure for the 3/16 inch model is 7500 psi (51.7 MPa, 517 bar).
The pressure switch should be set to 50 psi (3.4 bar, 0.34 MPa) to trigger the alarm.
The maximum allowable inlet pressure for a pressure feed pump is 100 psi (0.69 MPa, 6.9 bar).