This is a user manual that introduces the features and usage of the HYDRAULIC-100-V filter.
This user manual provides detailed instructions for installing, operating, and maintaining the HYDRAULIC-100-V self-cleaning mesh filter by ITM Filters. It includes sections on filter identification, hydraulic circuit operation, maintenance procedures, and control panel programming for both DC and AC models. The manual also covers technical specifications, pressure loss characteristics, and troubleshooting for common issues such as low pressure or endless loop problems.
The filter is designed for water filtration with automatic cleaning triggered by a pressure differential of 0.3 kg/cm². It features a modular backwash controller, hydraulic cleaning system, and adjustable wash cycles. Maintenance includes periodic manual cleaning of the mesh cartridge and battery checks for DC models.
| Maximum Operating Temperature | 50ºC |
|---|---|
| Working Pressure | Minimum: 2.5 kg/cm², Maximum: 10 kg/cm² |
| Filtration Degree | 125 microns |
| Battery Type (DC Model) | 4 alkaline batteries size 1.5"D" or 12v DC dry battery or 12v rechargeable battery with 2 watt solar panel |
| Operating Temperature (AC Model) | 0-60ºC |
The automatic cleaning cycle starts when the pressure difference between the inlet and outlet reaches 0.3 kg/cm².
The recommended flow rates vary by water quality: 53 m³/h for <50ppm, 26 m³/h for 50-100ppm, 19 m³/h for 100-200ppm, and 11 m³/h for >200ppm.
To manually activate the cleaning cycle, place the key in the 'OPEN' position.