This user manual provides detailed instructions for installing, operating, and maintaining the HYDRAULIC-100-V self-cleaning mesh filter by ITM Filters. It includes sections on filter identification, hydraulic circuit operation, maintenance procedures, and control panel programming for both DC and AC models. The manual also covers technical specifications, pressure loss characteristics, and troubleshooting for common issues such as low pressure or endless loop problems.

The filter is designed for water filtration with automatic cleaning triggered by a pressure differential of 0.3 kg/cm². It features a modular backwash controller, hydraulic cleaning system, and adjustable wash cycles. Maintenance includes periodic manual cleaning of the mesh cartridge and battery checks for DC models.

What's inside

  • Introduction
  • Quality Control
  • Data Sheet
  • Installation
  • Operation
  • Maintenance and Spare Parts
  • Control Panel
  • Technical Data

Specifications

Maximum Operating Temperature50ºC
Working PressureMinimum: 2.5 kg/cm², Maximum: 10 kg/cm²
Filtration Degree125 microns
Battery Type (DC Model)4 alkaline batteries size 1.5"D" or 12v DC dry battery or 12v rechargeable battery with 2 watt solar panel
Operating Temperature (AC Model)0-60ºC

Frequently asked questions

What triggers the automatic cleaning cycle?

The automatic cleaning cycle starts when the pressure difference between the inlet and outlet reaches 0.3 kg/cm².

What is the recommended flow rate for different water quality levels?

The recommended flow rates vary by water quality: 53 m³/h for <50ppm, 26 m³/h for 50-100ppm, 19 m³/h for 100-200ppm, and 11 m³/h for >200ppm.

How do I manually activate the cleaning cycle?

To manually activate the cleaning cycle, place the key in the 'OPEN' position.