Key facts
- Brand
- ITM Filters
- Model
- HYDRAULIC-100-V
- Category
- Industrial Robot
- Documents
- 2
- Languages
- EN · ES
- Last added
- 2023-10-21
Start here

ITM Filters HYDRAULIC-100-V Self-cleaning Mesh Filter User Manual
This user manual provides detailed instructions for installing, operating, and maintaining the HYDRAULIC-100-V self-cleaning mesh filter by ITM Filters. It includes sections on filter identification, hydraulic circuit operation, maintenance procedures, and control panel programming for both DC and AC models. The manual also covers technical specifications, pressure loss characteristics, and troubleshooting for common issues such as low pressure or endless loop problems.
The filter is designed for water filtration with automatic cleaning triggered by a pressure differential of 0.3 kg/cm². It features a modular backwash controller, hydraulic cleaning system, and adjustable wash cycles. Maintenance includes periodic manual cleaning of the mesh cartridge and battery checks for DC models.
ITM Filters HYDRAULIC-100-V specifications
| Maximum Operating Temperature | 50ºC |
|---|---|
| Working Pressure | Minimum: 2.5 kg/cm², Maximum: 10 kg/cm² |
| Filtration Degree | 125 microns |
| Battery Type (DC Model) | 4 alkaline batteries size 1.5"D" or 12v DC dry battery or 12v rechargeable battery with 2 watt solar panel |
| Operating Temperature (AC Model) | 0-60ºC |
Source: ITM Filters HYDRAULIC-100-V Self-cleaning Mesh Filter User Manual
All ITM Filters HYDRAULIC-100-V documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What triggers the automatic cleaning cycle?
The automatic cleaning cycle starts when the pressure difference between the inlet and outlet reaches 0.3 kg/cm².
From: ITM Filters HYDRAULIC-100-V Self-cleaning Mesh Filter User Manual
What is the recommended flow rate for different water quality levels?
The recommended flow rates vary by water quality: 53 m³/h for <50ppm, 26 m³/h for 50-100ppm, 19 m³/h for 100-200ppm, and 11 m³/h for >200ppm.
From: ITM Filters HYDRAULIC-100-V Self-cleaning Mesh Filter User Manual
What is the operating pressure range for the HYDRAULIC-100-V filter?
The operating pressure range is 2.5 to 10 kg/cm².
From: ITM Filters HYDRAULIC-100-V Automatic Cleaning Mesh Filter User Manual
What is the filtration grade of the HYDRAULIC-100-V filter?
The filtration grade is 125 microns.
From: ITM Filters HYDRAULIC-100-V Automatic Cleaning Mesh Filter User Manual