ITM Filters HYDRAULIC-200-H Self-Cleaning Mesh Filter User Manual

HYDRAULIC-200-H is a self-cleaning mesh filter, mainly used in hydraulic systems.


ITM Filters HYDRAULIC-200-H Self-Cleaning Mesh Filter User Manual - cover page
Brand
ITM Filters
Category
Other
Document type
User Manual
Language
Spanish
Pages
22
File format
PDF
File size
1.8 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
CFCF328289D0BD235A711C19C6C126B2

About this manual

This document is the user manual for the ITM Filters HYDRAULIC-200-H self-cleaning mesh filter. It provides instructions on installation, operation, and maintenance, including details on the hydraulic circuit and control panel programming. The manual covers various models within the HYDRAULIC-200-H series, such as the 204-H, 206-H, and 208-H. This manual is written in Spanish.

What's inside

  • Introducción
  • Control de calidad
  • Ficha técnica
  • Dimensiones
  • Circuito Hidráulico
  • Instalación
  • Funcionamiento
  • Mantenimiento y recambios
  • Panel de control
  • Garantía de producto

Specifications

Filtration Grade125 micras
Max Operating Temperature50ºC
Min Working Pressure2,5 kg/cm²
Max Working Pressure10 kg/cm²
Cleaning Activation Pressure0.3 kg/cm²

Frequently asked questions

How often should the filter mesh be manually cleaned?

The filter mesh requires periodic manual cleaning, which involves disconnecting power and water, draining the filter, and cleaning the cartridge.

What is the maximum operating temperature for the HYDRAULIC-200-H filter?

The filter is designed for a maximum operating temperature of 50ºC.

At what pressure difference does the automatic cleaning cycle begin?

The automatic cleaning cycle starts when the pressure difference reaches 0.3 kg/cm².

What is the standard duration of the cleaning cycle when it leaves the factory?

The cleaning cycle comes from the factory with a duration of 30 seconds.