Operating manual for micro annular gear pump mzr-6359 Ex, mzr-6359X2 Ex, mzr-7259 Ex, mzr-7259X2 Ex

This is an operating manual for a micro annular gear pump. It contains information on the pump's application range, product information, technical data, measurements, flow charts, Ex-motor and alternative brushless DC Ex-motor technical data.


Operating manual for micro annular gear pump mzr-6359 Ex, mzr-6359X2 Ex, mzr-7259 Ex, mzr-7259X2 Ex - cover page
Brand
HNP Mikrosysteme
Category
Other Electronics
Document type
User Manual
Language
English
Pages
96
File format
PDF
File size
1.6 MB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
11E5B4F89523FB6F74F7D6C226E2BDC3

About this manual

This operating manual provides instructions for the integration, operation, and maintenance of HNP Mikrosysteme micro annular gear pumps, specifically the MZR-6359 Ex, MZR-6359X2 Ex, MZR-7259 Ex, and MZR-7259X2 Ex models. The document details the application scope for various liquids, including solvents and oils, and outlines safety requirements for industrial use in Ex-certified environments.

What's inside

  • General information
  • Safety instructions
  • Transport and intermediate storage
  • Description of the micro annular gear pump
  • Optional modules
  • System integration
  • Startup/shutdown of a mzr-pump
  • Software Motion Manager
  • Maintenance and service
  • Declaration of conformity

Specifications

Displacement volume24 µl (MZR-6359) / 48 µl (MZR-7259)
Max. system pressure80 bar (1160 psi)
Flow rate Q0.024 - 112 ml/min (MZR-6359)
Explosion protection certificationCE II 2G IIC c T4

Frequently asked questions

What liquids are suitable for these pumps?

The pumps are suitable for water, watery solutions, solvents, methanol, oils, lubricating liquids, paints, and varnishes.

Can these pumps be used for invasive medical applications?

No, the micro annular gear pumps must not be used for invasive medical applications where liquid is re-introduced to the body.

What is the minimum dosage volume for the MZR-6359 Ex?

The minimum dosage volume for the MZR-6359 Ex is 15 µl.

Are these pumps suitable for aircraft use?

No, they must not be used in aircrafts and spacecrafts or other vehicles without prior consent of the manufacturer.