Operating manual for HNP Mikrosysteme's micro annular gear pumps, covering integration, operation, maintenance, safety, and technical data.
This manual provides detailed instructions for installing, operating, and maintaining the mzr-11508 and mzr-11508X1 micro annular gear pumps. It includes technical specifications, safety guidelines, fluid compatibility, and optional modules. The document also covers system integration with various controllers and software options like 'Composer', 'Motion Manager', and 'EPOS'. Safety and liability disclaimers are included, emphasizing proper use and adherence to regulations.
| Displacement Volume | 192 µl |
|---|---|
| Dimensions (L x W x H) | 333 x 110 x 125 mm (mzr-11508) |
| Weight | approx. 8 kg (mzr-11508) |
| Operating Pressure Range | 0 – 40 bar (Viscosity 1 mPas) |
| Viscosity Range | 0,5 – 150.000 mPas |
| Precision | < 1 % |
| Pulsation | 6 % (theoretical) |
| Operating Temperature | -5 … +60 °C (120 °C*) |
| Ambient Temperature | -5 … +50 °C |
| Store Temperature | 5 … +40 °C |
The maximum operating pressure is 40 bar for viscosity 1 mPas, 30 bar for 16 mPas, and 100 bar for 16 mPas under specific conditions.
The pump can be operated with controllers S-HV, S-HP-E, S-BL, S-HP-M, and S-HP, with corresponding software options like 'Composer', 'Motion Manager', and 'EPOS'.
The smallest dosage volume is 30 µl.