SPES™-108 Underwater Eddy Current Proximity Sensor User's Manual
This manual provides instructions for operating and installing the SPES-108 underwater eddy current proximity sensor, designed to measure blade tip clearance in Kaplan turbines and runner band clearance in Francis turbines. It includes details on connecting the sensor to power and instrumentation, assessing sensitivity using a target of the same material, and installing the sensor in turbine chambers. The sensor operates with a 0 to 8 mm range and outputs proportional current and voltage signals. Calibration and commissioning require following the manual’s procedures and contacting VibroSystM for final setup.
| Measuring Range | 0 to 8 mm (0 to 375 mils) |
|---|---|
| Output Current | 7.2-20 mA (proportional to sensor’s full range) |
| Output Voltage | 2 - 10 V (proportional to sensor's full range) |
| Power Supply | 24VDC |
The SPES-108 covers a 0 to 8 mm (0 to 375 mils) measuring range.
A target made of the same material as the real target, minimum 75mm x 75mm x 2mm, and measurements of distance vs. current output using spacers.
The sensor must be disconnected and reinstalled following the manual’s guidelines; failure to do so may result in incorrect measurements or damage.