Questions answered in VibroSystM manuals

What is the measuring range of the SPES-108 sensor?

The SPES-108 covers a 0 to 8 mm (0 to 375 mils) measuring range.

From: VibroSystM SPES-108 Underwater Eddy Current Proximity Sensor User's Manual

What is required to assess the sensor’s sensitivity?

A target made of the same material as the real target, minimum 75mm x 75mm x 2mm, and measurements of distance vs. current output using spacers.

From: VibroSystM SPES-108 Underwater Eddy Current Proximity Sensor User's Manual

What material is the sensor calibrated for?

The sensor is calibrated to produce a linearized output based on an FE360 steel target.

From: VibroSystM PES-110 Eddy Current Proximity Sensor User's Manual

What are the minimum dimensions for the target used during sensitivity assessment?

The minimum dimensions for the target are 50mm x 50mm x 2mm (2" x 2" x 1/16").

From: VibroSystM PES-110 Eddy Current Proximity Sensor User's Manual

What material is the sensor calibrated for?

The sensor is calibrated to produce a linearized output based on an FE360 steel target.

From: VibroSystM PES-103 Eddy Current Proximity Sensor User's Manual

What are the minimum dimensions for the target used during sensitivity assessment?

The minimum dimensions for the target are 50mm x 50mm x 2mm (2" x 2" x 1/16").