This manual introduces the use of Elma 2200x voltage tester, including safety precautions, intended use, instrument overview, preparing the instrument, measurements, battery replacement, technical data, etc.
This manual provides instructions for safely operating the Elma 2200x voltage tester. It covers voltage, continuity, RCD, and phase tests. The device meets CAT IV 600V and CAT III 1000V safety standards and can measure AC up to 1000V and DC up to 1500V. Safety precautions and proper usage are emphasized.
The manual includes sections on preparing the device, performing various tests, replacing batteries, and technical specifications such as measurement ranges, response time, and environmental ratings.
| Voltage Range | 6...1000V AC (40...400Hz), 6...1500V DC (±) |
|---|---|
| LCD Range | 6...1000V AC, 1500V DC (±) |
| Accuracy | ±3% ±3dgt (6...1000V AC/1500V DC) |
| Safety Category | CAT. III 1000V / CAT. IV 600V |
| Protection Rating | IP64 |
| Operating Temperature | -5...40°C |
| Battery Type | 2 x 1.5V IEC LR03 |
It measures AC up to 1000V and DC up to 1500V.
It has CAT III 1000V and CAT IV 600V safety ratings.
It automatically turns off after 30 seconds of inactivity.
It has an IP64 rating for protection against dust and water.