This manual describes the functions and features of Sysmon Monitor OnlinePRO, interfaces and commands, and provides examples.
The Sysmon Monitor OnlinePRO is a platform-independent system monitoring unit that monitors voltage, temperature, digital inputs, and fan speeds. It uses a 16-bit microcontroller with an integrated 12-bit A/D converter. Events triggered by exceeding configurable thresholds can activate predefined actions or control digital outputs. The unit supports web-based monitoring and can generate VME signals for VME systems. Configuration and monitoring are accessible via CLI, web interface, or RS232.
The manual details commands for voltage, temperature, and fan control, digital I/O configuration, and event-driven output control. It also covers pin assignments, technical specifications, and optional FanCon OnlinePRO module integration. This manual is written in German.
| Voltage Monitoring | Up to 8 voltages (5 positive, 3 negative) with individually configurable upper and lower thresholds |
|---|---|
| Temperature Monitoring | Up to 6 analog temperature sensors (10K Ohm NTC thermistors with β=3950), range -20°C..+100°C, accuracy ±3°C (max.) |
| Fan Monitoring and Control | Up to 12 fans, with configurable minimum speed (>700rpm), PWM speed control (20Hz..10KHz), and soft start |
| Digital I/O | 16 digital inputs (2x 8-bit ports) and 16 digital outputs (2x 8-bit ports), 5V TTL logic, 20mA load capability |
| VME Signal Generation | Generates VME signals ACFAIL and SYSRESET per ANSI/VITA 1-1994 specification |
Up to 8 voltages (5 positive, 3 negative) can be monitored with individually configurable upper and lower thresholds.
Temperature monitoring range is -20°C to +100°C with an accuracy of ±3°C (max.).
Yes, it generates VME signals ACFAIL and SYSRESET according to ANSI/VITA 1-1994 specification.
Digital outputs can be manually set or reset via CLI commands or automatically controlled by internal or external events using mask configurations.