ELMA Sysmon Monitor OnlinePRO User Manual

This manual describes the functions and features of Sysmon Monitor OnlinePRO, interfaces and commands, and provides examples.


ELMA Sysmon Monitor OnlinePRO User Manual - cover page
Brand
ELMA
Document type
User Manual
Language
German
Pages
36
File format
PDF
File size
839 KB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
54035AF37401ADCCE5199AEAB119E7A8

About this manual

The Sysmon Monitor OnlinePRO is a platform-independent system monitoring unit that monitors voltage, temperature, digital inputs, and fan speeds. It uses a 16-bit microcontroller with an integrated 12-bit A/D converter. Events triggered by exceeding configurable thresholds can activate predefined actions or control digital outputs. The unit supports web-based monitoring and can generate VME signals for VME systems. Configuration and monitoring are accessible via CLI, web interface, or RS232.

The manual details commands for voltage, temperature, and fan control, digital I/O configuration, and event-driven output control. It also covers pin assignments, technical specifications, and optional FanCon OnlinePRO module integration. This manual is written in German.

What's inside

  • Product Description and Functions
  • Voltage Monitoring
  • Temperature Monitoring
  • Fan Monitoring and Control
  • Digital Inputs and Outputs
  • VME Signal Generation
  • Ethernet Interface
  • Serial RS232 Interface
  • Web Interface
  • Command Line Interface (CLI)

Specifications

Voltage MonitoringUp to 8 voltages (5 positive, 3 negative) with individually configurable upper and lower thresholds
Temperature MonitoringUp to 6 analog temperature sensors (10K Ohm NTC thermistors with β=3950), range -20°C..+100°C, accuracy ±3°C (max.)
Fan Monitoring and ControlUp to 12 fans, with configurable minimum speed (>700rpm), PWM speed control (20Hz..10KHz), and soft start
Digital I/O16 digital inputs (2x 8-bit ports) and 16 digital outputs (2x 8-bit ports), 5V TTL logic, 20mA load capability
VME Signal GenerationGenerates VME signals ACFAIL and SYSRESET per ANSI/VITA 1-1994 specification

Frequently asked questions

How many voltage channels can be monitored?

Up to 8 voltages (5 positive, 3 negative) can be monitored with individually configurable upper and lower thresholds.

What is the temperature monitoring range and accuracy?

Temperature monitoring range is -20°C to +100°C with an accuracy of ±3°C (max.).

Can the unit generate VME signals?

Yes, it generates VME signals ACFAIL and SYSRESET according to ANSI/VITA 1-1994 specification.

How are digital outputs controlled?

Digital outputs can be manually set or reset via CLI commands or automatically controlled by internal or external events using mask configurations.