This document is the operating instructions manual for the Sylvania Serpentine II & Serpentine VI air heaters
This manual provides operating instructions for the Sylvania Serpentine II and Serpentine VI air heaters. These compact and efficient units are designed to heat process air or inert gas, with exit temperatures reaching up to 1400°F (760°C) for standard elements and 1500°F (815°C) for 2-Stage elements. The heaters consist of a replaceable serpentine-coil element housed in a stainless steel triple-pass exchanger.
| Maximum Exit Air Temperature (Standard) | 1400°F (760°C) |
|---|---|
| Maximum Exit Air Temperature (2-Stage) | 1500°F (815°C) |
| Maximum Inlet Pressure | 25 PSI (1.7 BAR) |
| Maximum Inlet Air Temperature | 200°F (93°C) |
| Minimum Airflow (Serpentine II) | 60 SCFH (28.3 SLPM) |
| Minimum Airflow (Serpentine VI) | 120 SCFH (56.6 SLPM) |
| Typical Element Life | 5000 hours |
The typical element life is approximately 5000 hours if operated at or below temperatures shown on the performance curve.
No, on-off controllers may shorten heater life or cause the element to burn out; phase angle fired power controllers are recommended.
Osram-Sylvania recommends using an exposed junction type K thermocouple located within one inch of the heater exit.
Allow air to continue to flow for a minimum of one minute or until the exit air temperature is 300°F (150°C) or less.