This manual contains the user manual of BVFD161, BVFD163, BVFD163WD adjustable frequency drives, which introduces the features and characteristics of the drives and how to use them.
This manual provides instructions for the Bronco VFD Series, solid-state variable-frequency AC motor drives manufactured by Danaher Motion. The drives are designed for 1.5 HP or smaller, 208/230-volt three-phase-AC induction and single-phase permanent split capacitor motors. They feature a 115 or 230 VAC, 50/60 Hz single-phase input and are factory calibrated for an output of 0 to 60 Hz, with user calibration options up to 120 Hz.
| Max Output Amps | 4.0 (BVFD163/BVFD163WD), 5.0 (BVFD161) |
|---|---|
| Output Frequency Range | 0 – 120 Hz |
| Maximum Output Frequency Range | 30 – 120 Hz |
| Acceleration Time Range | 1 – 12 seconds |
| Deceleration Time Range | 1 – 12 seconds |
| Analog Input Voltage Range | 0 – 5VDC, 0-10VDC, 4-20mA |
| Ambient Operating Temperature Range | 10° – 40° C |
The drive operates 1.5 HP or smaller, 208/230-volt three-phase-AC induction and single-phase permanent split capacitor motors.
Yes, the drives can be user calibrated for an output range of 0 through 120 Hz.
The standard carrier frequency is 16 KHz.
Yes, isolation is standard, allowing non-isolated speed input, enable, and direction switch inputs.