CommScope PMT200B Series DryLine Dehydrator User Manual

This is a user manual for a DryLine® DEHYDRATOR. It mainly introduces the product's function characteristics, installation methods, operation methods, etc.


CommScope PMT200B Series DryLine Dehydrator User Manual - cover page
Brand
CommScope
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
961 KB
Published
20 October, 2023
Updated
20 October, 2023
Model
PMT200B
MD5 checksum
CAE1768365AD97583175C727EABCC28D

About this manual

The CommScope PMT200B Series DryLine dehydrator is designed to provide dry air for pressurizing small antenna and transmission line systems, typically up to 1700 liters in volume. It produces air with a dew point of -45°C (-50°F) at an output rate of 5.7 SLPM. The unit features an electrically driven air compressor, a membrane dryer assembly, and an automatic transmission line pressure sensing system housed in a rigid metal chassis. It is intended for wall mounting or as a free-standing unit.

What's inside

  • General Information
  • Installation
  • Operation
  • Maintenance
  • Troubleshooting
  • Replacement Parts
  • Customer Service
  • DC Inverter Option

Specifications

Output Dew Point-45° C (-50° F)
Output Capacity5.6 SLPM (0.2 SCFM)
Operating Temperature Range-10° to +50° C
Electrical Input115 ±10% Vac, 60 Hz
Output Connector3/8” polytube
Net Weight16.55 kg (36 1/2 lb)

Frequently asked questions

What is the default password for the keypad?

The default password is 1111.

What is the factory setting for the Excess Run Alarm?

The factory setting is 10 minutes.

At what pressure does the Low Pressure Alarm activate?

The alarm activates if system pressure falls below 6.9 kPa (1.0 psig).