About this manual

The PMT200B Series DryLine dehydrators provide dry air with a dew point of -45°C (-50°F) at an output rate of 5.7 SLPM (0.2 SCFM). Designed for standard microwave antenna applications, the unit maintains transmission line pressures up to 41.4 kPa (6.0 psig) and is intended for systems with a volume up to 1700 liters.

What's inside

  • General Information
  • Installation
  • Power Connections
  • Connecting Alarm Outputs
  • Checking Individual Line Pressures
  • Purging the Transmission Line
  • Adjusting Output Pressure
  • Regular Maintenance
  • Preventive Maintenance
  • Troubleshooting

Specifications

Output Dew Point-45° C (-50° F) or better
Output Rate5.7 SLPM (0.2 SCFM)
System Volume CapacityUp to 1700 liters (60 ft³)
Output Pressure Range13.8 kPa (2.0 psig) to 41.4 kPa (6.0 psig)
Operating Temperature Range-10° to +50°C (41°F to +122°F)
Electrical Input115 Vac, 60 Hz or 240 Vac, 50 Hz
Low Pressure Alarm Trigger6.9 kPa (1.0 psig)

Frequently asked questions

What is the default factory run time for the Excess Run alarm?

The default setting used on the PMT200B is 10 minutes.

How often does the dehydrator cycle when connected to a very tight system?

It will cycle approximately every 60 minutes.

What happens when power is removed from the dehydrator?

The Power Fail alarm activates.