Installation instructions and specifications for CommScope Wall/Roof Feed-through Plates for waveguides and coaxial cables, including dimensions and part…
This document provides installation instructions and specifications for CommScope's Wall/Roof Feed-through Plates designed for waveguides and coaxial cables. It includes details on wall opening sizes, overall dimensions, and specific part numbers for various configurations.
The guide outlines the required hole sizes for plastic screw anchors used in masonry, metal, or plastic walls (5/16"x1-38"). It also details the application of sealant to frames, plates, screws, edges, roof surfaces, and flashing to ensure proper installation.
| Hole size for plastic screw anchor | 5/16"x1-38" (8x35 mm) |
|---|
The installation requires a 5/16"x1-38" (8x35 mm) hole.
You must apply sealant to the frame and plate, as well as to the screws and edges of the plate.
Tar is applied to the roof and metal flashing, while sealant is applied to the bottom and top of the wood frame.