This manual introduces the installation, operation, and maintenance of the HIGH-FLO SERIES Surge Tanks products, which are suitable for professionals
This manual provides step-by-step instructions for installing, operating, and maintaining Graco HIGH-FLO series surge tanks. It covers grounding requirements, mounting procedures, fluid line connections, and safety precautions. Specific sections address different models, including Model 233736 and others, with detailed technical data and troubleshooting guidance. Safety warnings are emphasized throughout to prevent injury or equipment damage.
The maximum fluid working pressure for Model 233736 is 360 psi (2.5 MPa, 25 bar).
You must use a minimum 51 mm (2 in.) diameter pipe and plumbing for these models.
Secure the stand to the floor with M19 (5/8 in.) bolts.