The Signet 2350 Temperature Sensor has a one-piece injection molded PVDF body that is ideal for use in high purity applications. It also outlasts metal sensors in aggressive liquids and eliminates the need for costly custom thermowells. These sensors are available with Digital (S3L) or field-scaleable 4 to 20 mA output. Dual threaded ends (3/4 in. NPT) allow submersion in process vessels, or in-line installation with conduit connection. Integral adapters (sold separately) may be used to create a compact assembly with field mount style of the 9900 Transmitter.
This manual covers installation, wiring, and specifications for the Signet 2350 temperature sensor. It includes details on mounting, cable connections, and environmental limits. The sensor is designed for high-purity applications and can be installed in-line or submersed, with temperature ranges up to 100°C or 85°C respectively. Safety and compatibility guidelines are also provided.
| Measurement Range (In-line) | -10°C to 100°C (14°F to 212°F) |
|---|---|
| Measurement Range (Submersible) | -10°C to 85°C (14°F to 185°F) |
| Process Connection | 3/4 in. NPT male thread |
| Cable Type | 3 cond + shield, 22 AWG |
| Standard Cable Length | 4.6 m (15 ft) |
| Electrical Power (S3L) | 5 VDC ±10%, <1.5 mA |
| Electrical Power (4-20mA) | 12-24 VDC ±10% |
| Accuracy (Digital) | ±0.5 °C (±0.9 °F) |
| Resolution (Digital) | 0.01 °C (0.02 °F) |
| Update Rate (Digital) | <100 ms |
| Accuracy (4-20mA) | ±32 μA |
| Max Loop Impedance (12V) | 50 Ω |
| Environmental Relative Humidity | 0 to 95% (Non-condensing) |
| Storage Temperature | -55 °C to 100 °C (-67 °F to 212 °F) |
Submersible installations are limited to 85 °C (185 °F).
The 4-20mA models require 12-24 VDC ±10%.
The response time is 10 seconds.
The sensor has a one-piece injection molded PVDF body.