Signet 2350 Temperature Sensor User Manual

The Signet 2350 Temperature Sensor has a one-piece injection molded PVDF body that is ideal for use in high purity applications. It also outlasts metal sensors in aggressive liquids and eliminates the need for costly custom thermowells. These sensors are available with Digital (S3L) or field-scaleable 4 to 20 mA output. Dual threaded ends (3/4 in. NPT) allow submersion in process vessels, or in-line installation with conduit connection. Integral adapters (sold separately) may be used to create a compact assembly with field mount style of the 9900 Transmitter.


Signet 2350 Temperature Sensor User Manual - cover page
Brand
Signet
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
435 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
F577D41CEAF0B0B6116ED93E24BAC3E3

About this manual

This manual covers installation, wiring, and specifications for the Signet 2350 temperature sensor. It includes details on mounting, cable connections, and environmental limits. The sensor is designed for high-purity applications and can be installed in-line or submersed, with temperature ranges up to 100°C or 85°C respectively. Safety and compatibility guidelines are also provided.

What's inside

  • Installation
  • Wiring
  • Specifications
  • Safety Information
  • Product Registration

Specifications

Measurement Range (In-line)-10°C to 100°C (14°F to 212°F)
Measurement Range (Submersible)-10°C to 85°C (14°F to 185°F)
Process Connection3/4 in. NPT male thread
Cable Type3 cond + shield, 22 AWG
Standard Cable Length4.6 m (15 ft)
Electrical Power (S3L)5 VDC ±10%, <1.5 mA
Electrical Power (4-20mA)12-24 VDC ±10%
Accuracy (Digital)±0.5 °C (±0.9 °F)
Resolution (Digital)0.01 °C (0.02 °F)
Update Rate (Digital)<100 ms
Accuracy (4-20mA)±32 μA
Max Loop Impedance (12V)50 Ω
Environmental Relative Humidity0 to 95% (Non-condensing)
Storage Temperature-55 °C to 100 °C (-67 °F to 212 °F)

Frequently asked questions

What is the maximum temperature for submersible installation?

Submersible installations are limited to 85 °C (185 °F).

What are the power requirements for the 4-20mA models?

The 4-20mA models require 12-24 VDC ±10%.

What is the response time of the sensor?

The response time is 10 seconds.

What materials is the sensor body made of?

The sensor has a one-piece injection molded PVDF body.