This manual provides information on how to operate and install the Rinnai ES11 Energysaver Gas Direct Vent Wall Furnace
The Rinnai ES11 Energysaver Gas Direct Vent Wall Furnace is a forced combustion, forced convection appliance designed for residential or commercial settings. It features electronic ignition, a humidifier tray, and sensible temperature control to maintain comfortable room temperatures. The unit is convertible for use with natural gas or liquefied petroleum gases (propane) and is suitable for installation at altitudes up to 10,200 feet.
| Gas Connection | 1/2 in female NPT |
|---|---|
| Electrical Connection | AC 120V, 60 Hz, 47 watts |
| Weight | 37 lbs (17 kg) |
| Noise Level | 31-38 dB |
| AFUE Rating (Natural Gas) | 80.0% |
| AFUE Rating (Propane) | 80.0% |
| Humidifier Tray Capacity | 1.5 pints (700 cc) |
| Maximum Altitude | 10,200 feet (3109 m) |
Do not try to light any appliance, do not touch any electrical switch, and immediately call your gas supplier from a neighbor's phone.
Yes, the appliance is convertible for use with liquefied petroleum gases (propane / LPG) when provision is made for the simple conversion.
The appliance will automatically turn off and a fault code will be displayed on the control panel.
Press the ON/OFF button; the LED display will illuminate, the combustion fan will begin to run, and the spark will ignite the main burner.