Rinnai Tankless Water Heater Sizing Guidelines
This document provides sizing guidelines for Rinnai tankless water heaters, intended as a guide rather than a replacement for professionally engineered systems. It lists hot water usage rates in GPM for various fixtures, such as tubs, showers, and kitchen faucets, noting specific assumptions like the use of one standard showerhead per shower.
| Tub & Shower Fixtures Usage | 1.5 GPM |
|---|---|
| Lavatories Usage | 0.5 GPM |
| Kitchen faucets Usage | 1.4 GPM |
| Residential Dishwashers Usage | 1.5 GPM |
| Residential Washers Usage | 1.5 GPM |
| Utility Sinks Usage | 1.5 GPM |
| Laundry Sinks Usage | 1.5 GPM |
| V65 Flow Rate at 50/60F Rise | 5.0 GPM |
| RL75 Flow Rate at 50/60F Rise | 6.0 GPM |
| V75 Flow Rate at 50/60F Rise | 6.0 GPM |
| RLX94 Flow Rate at 50/60F Rise | 6.4 GPM |
| RU180 Flow Rate at 50/60F Rise | 5.9 GPM |
| RUC90 Flow Rate at 50/60F Rise | 7.0 GPM |
| RU199 Flow Rate at 50/60F Rise | 7.6 GPM |
| RUR199 Flow Rate at 50/60F Rise | 7.7 GPM |
| Minimum circulation loop flow rate | 3 gpm |
The flow rate for the V65 model is 5.0 GPM at a 50/60F rise.
No, unless a booster heater capable of producing 180-195ºF water is provided at the dishwasher.
The piping systems should be designed with a hot water circulation loop having a minimum flow rate of 3 gpm.