This manual includes design steps, technical data, design layouts, as well as some design and installation details and checklists.
This document serves as a design guide for the Netafim Techline DL integral dripline system. It covers the basics of design, installation, and maintenance, specifically utilizing a 'grid' layout method to ensure complete wetted areas. The guide is intended for subsurface applications but is also applicable to on-surface installations.
| Maximum Zone Flow | 5 GPM |
|---|---|
| Emitter Flow Rates | 0.26, 0.4, 0.6, 0.9 GPH |
| Emitter Spacing | 12" or 18" |
| Burial Depth | 4" to 6" |
| Tubing Diameter | 17mm |
| Line Flushing Valve Model | TLFV-1 |
This type of design is intended for subsurface applications but can be applied to on-surface installations as well.
Headers should be indented 2 inches to 4 inches from hardscapes and planting areas.
Install the Line Flushing Valve in an inconspicuous area as far away from the source as possible.