This manual provides instructions on how to install the hardware of Moxa TCC-100 series.
This guide explains how to install Moxa TCC-100 series media converters, which convert RS-232 signals to RS-422/485 for industrial networking. It covers hardware setup, termination resistor configuration, and wiring options including DIN-rail and wall mounting. The converters support 2 kV isolation (in I/T models), auto baudrate detection, and ADDC™ for RS-485 data direction control. Installation requires verifying package contents, connecting power and RS-232/485 cables, and testing the connection with terminal software.
| Communication RS-232 Signal | Supports Tx, Rx, RTS, CTS; Female DB9 interface |
|---|---|
| RS-422/485 Signal | Terminal block connector (DIP Switch selectable) |
| Baudrate | 50 bps to 921.6 Kbps |
| Isolation | 2 kV (TCC-100I/TCC-100I-T) for both power and signal |
| Operating Temperature | TCC-100/TCC-100I: -20 to 60°C ( -4 to 140°F) TCC-100-T/TCC-100I-T: -40 to 85°C ( -40 to 185°F) |
| Power Consumption | TCC-100/TCC-100-T: 85 mA @ 12 V TCC-100I/TCC-100I-T: 150 mA @ 12 V |
| Dimensions | 67 × 100 × 22 mm (without ears) 90 × 100 × 22 mm (with ears) |
Up to 1.2 km for 4-wire RS-422 and 2/4-wire RS-485.
It uses ADDC™ (Automatic Data Direction Control) to automatically sense and control data direction, eliminating the need for handshaking signals.
External power from 12 to 48 VDC, with reverse power protection.