This manual provides detailed instructions on how to install the unit, including preparation before installation, indoor unit installation, outdoor unit installation, pipe connection, refrigerant filling and other processes.
This manual provides installation instructions for Changhong floor type air conditioners, specifically models MFZ-KJ25VE2, MFZ-KJ35VE2, and MFZ-KJ50VE2. It emphasizes that installation must be performed by a qualified installer and outlines critical safety precautions regarding electrical work, refrigerant handling, and physical securing of the units. The document specifies that the refrigerant used is R410A and highlights the higher pressure compared to R22, requiring appropriate tools and materials to prevent pipe bursts or injury.
The guide details the selection of installation locations for indoor and outdoor units, ensuring proper airflow, drainage, and distance from heat sources or interference with radio/TV reception. It covers the steps for indoor and outdoor unit installation, flare and pipe connections, purging procedures, leak testing, and the final pumping down of the refrigerant system.
| Refrigerant Type | R410A |
|---|---|
| Refrigerant Pressure Factor | 1.6 times more than R22 |
| Minimum Distance from TV/Radio | 1 m or more |
| Minimum Distance from TV/Radio Antenna (Outdoor) | 3 m |
The installation must be performed by a qualified installer or dealer, not by the user.
Required tools include a Phillips screwdriver, level, scale, utility knife, hole saw, torque wrench, wrench, 4 mm hexagonal wrench, flare tool for R410A, gauge manifold, vacuum pump, charge hose, and pipe cutter with reamer.