RayBio® Mouse TIM1 IQELISA Kit is a new assay kit developed by RayBio company to measure the level of Mouse TIM1 in serum, plasma, and cell culture supernatants. The kit uses an antibody specific for Mouse TIM1 coated on a 96-well PCR plate and a real-time PCR detection method to provide high sensitivity and specificity.
This document provides detailed instructions for using the RayBio® Mouse TIM1 IQELISA Kit, which combines ELISA specificity with qPCR sensitivity. It includes sections on reagents, storage, preparation, assay procedure, and result calculation. The kit uses a 96-well PCR plate coated with anti-Mouse TIM1 antibody and requires a real-time PCR instrument for data collection.
The manual outlines step-by-step procedures for preparing reagents, adding samples and standards, washing wells, incubating with detection reagents, and running qPCR. It also explains how to calculate results using Ct values and provides typical data and sensitivity information.
| Minimum Quantifiable Dose | 1.95 pg/ml |
|---|---|
| Recovery Rate | 146% (range 138% to 157%) |
| Intraplate CV | Below 10% |
| Interplate CV | Below 15% |
The minimum quantifiable dose of TIM1 is typically 1.95 pg/ml.
Serum spike tests show recovery is 146% with a range from 138% to 157%.
Intraplate CV is below 10% for all samples.
Interplate CV is below 15%.