This manual introduces the features and usage methods of the HMS-1FL series horizontal multi-stage jet pumps, including deep well installation, shallow well installation and pump starting methods.
This document is the Owner's Manual for the Pentair HMS-1FL Series of Horizontal Multi-Stage Jet Pumps. It covers models with 3/4 HP, 1 HP, and 1-1/2 HP ratings. The guide includes specific procedures for deep well and shallow well installations, as well as instructions for priming the pump and adjusting the regulator valve.
| Models | 3/4 HP, 1 HP, 1-1/2 HP |
|---|---|
| Pressure Switch Range (HMSD, HMSE, HMSF) | 30-50 PSI |
| Pressure Switch Range (HMSC) | 20-40 PSI |
| Tank Pre-charge (20-40 PSI switch) | 18 PSI |
| Tank Pre-charge (30-50 PSI switch) | 28 PSI |
Install a pressure relief valve capable of passing entire pump flow at 75 PSI.
Completely close the priming valve, fill the regulator with clean water, start the pump, and slowly open the regulator valve until the correct pressure is reached.
The maximum distance is 100 feet.
The warranty is 12 months from the date of original installation or 18 months from the date of manufacture, whichever occurs first.