This operating manual provides information on how to use Hollis BOV (bail out valve).
The Hollis BOV (Bail Out Valve) is a safety device designed for divers using closed-circuit rebreathers. It functions as an open-circuit bailout regulator, allowing the diver to breathe from a separate gas supply in an emergency. The manual outlines two primary operating modes: Closed Circuit (CC) for normal rebreather use and Open Circuit (OC) for emergency bailout. It emphasizes the importance of proper training, regular inspection, and correct handling to ensure safety and prevent equipment failure.
| Supply Pressure Requirement | 137 - 148 psi (9.4 - 10.2 bar) |
|---|---|
| Nitrox Compatibility | Up to 40% oxygen |
| Cold Water Limit | 50 °F/10°C |
The recommended sanitizer is Steramine solution.
The BOV requires a supply pressure of 137 - 148 psi (9.4 - 10.2 bar) for proper breathing performance.
The Explorer Prism 2 configuration is recommended for depths from surface to 30 ft (9.1 m).
The manual recommends using Tribolube 71 or CHRISTO-LUBE MCG 111 for lubrication.