Hollis 500SE Second Stage Service Procedure

This is a second stage service procedure that provides troubleshooting tips and solutions.


Hollis 500SE Second Stage Service Procedure - cover page
Brand
Hollis
Category
Other
Document type
Service Manual
Language
English
Pages
17
File format
PDF
File size
2.6 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
1669BDC0C74260D8306D707B82289BBB

About this manual

This document provides a service procedure for the Hollis 500SE second stage regulator. It includes a troubleshooting section that lists symptoms, possible causes, and treatments for issues such as free-flow, air leakage, and excessive inhalation resistance. The guide details specific steps for disassembly, including the removal of the mouthpiece, retainer, housing, and internal valve components.

What's inside

  • Troubleshooting
  • Disassembly Procedure
  • Reassembly Procedure
  • Final Tuning and Testing
  • Parts List and Exploded View Diagram
  • General Procedures
  • Specifications
  • Tools Required

Specifications

Torque: LP Hose35 to 40 in-lbs (4-4.5 N-M)
Torque: Control Valve Screw18 to 20 in-lbs (2.0-2.2 N-M)
Acceptable Setup Range1.0 to 1.6 inches of water
Intermediate Pressure Limitno more than 145 psi

Frequently asked questions

What tools are required for disassembly?

Standard tools include a small flat blade screwdriver, 4" deep wall socket, 9/16" open end wrench, 13/16" open end wrench, 15/16" open end wrench, wooden dowel, and O-ring picks.

What lubricant is recommended for service?

Hollis approved Halocarbon Based Lubricant is required.

Download PDF (2.6 MB)

More Hollis Manuals


View all Hollis manuals →