This document introduces the use of CO2 sensor, including assembly, disassembly, maintenance, etc.
This manual provides instructions for installing, calibrating, and maintaining the Hollis Explorer CO2 sensor, including handling silica beads to prevent moisture interference. It includes critical safety warnings about proper use and calibration to avoid serious injury or death. The sensor is designed for use only with the Hollis Explorer rebreather system and must be calibrated before each dive.
It is intended for use in detecting channeling, high work rates, bad absorbent material, and other possible failures of the Explorer scrubber system.
Heat the silica beads in an oven at 225°F for about an hour until they return to their original amber color.
The Explorer rebreather scrubber is a maximum two hour duration scrubber when used under sport diving conditions.