This is an instruction manual for the Bubble‐Up® Interactive radon removal system.
This document provides step-by-step installation and operating instructions for the Bubble‐Up® Interactive™ radon removal system by R.E. Prescott Co., Inc. It covers plumbing, electrical, and component setup, including bypass valve operation, water alarm valve setup, and vent line installation. Safety precautions are emphasized, such as avoiding overlong vent lines and ensuring proper electrical wiring. The system uses a bubbling action to release radon from water and vent it safely outdoors.
| Dimensions | Depth: 30”, Width: 25”, Tank Height: 41”, Overall Height: 60” |
|---|---|
| Water Capacity | On/Off Cycle Volume: 15 Gallons |
| Weight | 125 lb. empty, 567 lb. filled to 26” depth, 792 lb. filled to 41” depth |
| Influent Water Requirements | Hardness < 68 mg/l (4 GPG), Iron < 0.03 mg/l, Manganese <0.05 mg/l |
| Electrical Requirements | Dedicated 20A circuit, quadplex outlet, 115V AC #12 AWG wiring |
| Pump | 1/2 HP high pressure (75 p.s.i.) submersible pump, 10.6 A maximum @ 115V |
| Blower | 4.5A, 115V AC |
| Radon Removal Efficiency | 99% at 7 GPM, 98% at 14 GPM |
The maximum water depth is 26 inches (off float switch level).
A dedicated 20A circuit, quadplex outlet, 115V AC, and #12 AWG wiring.
The unit removes 99% of radon at 7 GPM.
The valve shuts off water supply to prevent leaks or obstructions; reset by holding the reset button for three seconds.