R.E. Prescott Co., Inc. Bubble‐Up® Interactive™ Radon Removal System Installation and Operating Instructions

This is an instruction manual for the Bubble‐Up® Interactive radon removal system.


R.E. Prescott Co., Inc. Bubble‐Up® Interactive™ Radon Removal System Installation and Operating Instructions - cover page
Brand
R.E. Prescott Co., Inc.
Category
Health Care
Document type
Installation Guide
Language
English
Pages
30
File format
PDF
File size
863 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
DE60998E4E38E0A0C10DB6C1B626A9CC

About this manual

This document provides step-by-step installation and operating instructions for the Bubble‐Up® Interactive™ radon removal system by R.E. Prescott Co., Inc. It covers plumbing, electrical, and component setup, including bypass valve operation, water alarm valve setup, and vent line installation. Safety precautions are emphasized, such as avoiding overlong vent lines and ensuring proper electrical wiring. The system uses a bubbling action to release radon from water and vent it safely outdoors.

What's inside

  • Specifications
  • Installation
  • Controls and Indicators
  • Operating Instructions
  • Maintenance
  • Troubleshooting
  • Replacement Parts Listing
  • Start‐Up Data
  • Appendix A‐ 7 gpm Mechanical Head Manual
  • Appendix B‐ Meter Control Manual

Specifications

DimensionsDepth: 30”, Width: 25”, Tank Height: 41”, Overall Height: 60”
Water CapacityOn/Off Cycle Volume: 15 Gallons
Weight125 lb. empty, 567 lb. filled to 26” depth, 792 lb. filled to 41” depth
Influent Water RequirementsHardness < 68 mg/l (4 GPG), Iron < 0.03 mg/l, Manganese <0.05 mg/l
Electrical RequirementsDedicated 20A circuit, quadplex outlet, 115V AC #12 AWG wiring
Pump1/2 HP high pressure (75 p.s.i.) submersible pump, 10.6 A maximum @ 115V
Blower4.5A, 115V AC
Radon Removal Efficiency99% at 7 GPM, 98% at 14 GPM

Frequently asked questions

What is the maximum water depth for the Bubble‐Up® Interactive™ unit?

The maximum water depth is 26 inches (off float switch level).

What electrical requirements does the unit need?

A dedicated 20A circuit, quadplex outlet, 115V AC, and #12 AWG wiring.

What is the radon removal efficiency at 7 GPM?

The unit removes 99% of radon at 7 GPM.

What should I do if the water alarm valve activates?

The valve shuts off water supply to prevent leaks or obstructions; reset by holding the reset button for three seconds.

Download PDF (863 KB)

More R.E. Prescott Co., Inc. Manuals


View all R.E. Prescott Co., Inc. manuals →