Bubble-Up Jr Interactive™ Radon Removal System Installation and Operating Instructions
This manual provides step-by-step installation and operating instructions for the Bubble-Up® Jr Interactive™ radon removal system by R.E. Prescott Co., Inc. It covers specifications, controls, installation procedures, operation, maintenance, and troubleshooting. The system uses air bubbling to remove radon from water and includes safety features like a water alarm valve and float switches. It is designed for residential or commercial use and requires specific plumbing and electrical connections.
| Dimensions | Depth: 18”, Width: 24”, Tank Height: 41”, Overall Height: 60” |
|---|---|
| Water Capacity | Usable water at maximum water depth of 26”: 34 Gallons |
| Weight | 90 lb. empty, 373 lb. filled to maximum water depth of 26” |
| Influent Water Requirements | Hardness < 68 mg/l (4 GPG), Iron < 0.03 mg/l, Manganese <0.05 mg/l |
| Pump | 1/2 HP high pressure (75 p.s.i.) submersible pump |
| Blower | 4.5A, 115V AC |
The unit requires 1” male NPT water inlet and outlet bypass valve, 2” FNPT air inlet, 2” Fernco air outlet, 1.25” FNPT overflow connection, and 3/4” male NPT for expansion tank.
A dedicated 20A circuit, Quadplex outlet, 115V AC, #12 AWG wiring.