R.E. Prescott Co., Inc. Bubble-Up® Jr Interactive™ Radon Removal System Installation and Operating Instructions

Bubble-Up Jr Interactive™ Radon Removal System Installation and Operating Instructions


R.E. Prescott Co., Inc. Bubble-Up® Jr Interactive™ Radon Removal System Installation and Operating Instructions - cover page
Brand
R.E. Prescott Co., Inc.
Category
Health Care
Document type
User Manual
Language
English
Pages
30
File format
PDF
File size
897 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
769F0C6D02477F2A6E11A154FD1A4914

About this manual

This manual provides step-by-step installation and operating instructions for the Bubble-Up® Jr Interactive™ radon removal system by R.E. Prescott Co., Inc. It covers specifications, controls, installation procedures, operation, maintenance, and troubleshooting. The system uses air bubbling to remove radon from water and includes safety features like a water alarm valve and float switches. It is designed for residential or commercial use and requires specific plumbing and electrical connections.

What's inside

  • Specifications
  • Inlet and Outlet Flow and Pressure Specifications
  • Controls and Indicators
  • Installation
  • Start-Up Procedure
  • Operating Instructions
  • Maintenance
  • Troubleshooting
  • Replacement Parts Listing
  • Start-Up Data

Specifications

DimensionsDepth: 18”, Width: 24”, Tank Height: 41”, Overall Height: 60”
Water CapacityUsable water at maximum water depth of 26”: 34 Gallons
Weight90 lb. empty, 373 lb. filled to maximum water depth of 26”
Influent Water RequirementsHardness < 68 mg/l (4 GPG), Iron < 0.03 mg/l, Manganese <0.05 mg/l
Pump1/2 HP high pressure (75 p.s.i.) submersible pump
Blower4.5A, 115V AC

Frequently asked questions

What are the plumbing connections required?

The unit requires 1” male NPT water inlet and outlet bypass valve, 2” FNPT air inlet, 2” Fernco air outlet, 1.25” FNPT overflow connection, and 3/4” male NPT for expansion tank.

What is the electrical requirement?

A dedicated 20A circuit, Quadplex outlet, 115V AC, #12 AWG wiring.