JBMB-56S - JBMB-63S series centrifugal pump installation and operation instructions
This document provides installation and operating instructions for Pentair’s J-Series centrifugal pumps, including models JBMB-56S and JBMB-63S. It covers piping requirements, priming procedures, electrical wiring, and mechanical seal replacement. The guide emphasizes proper pipe sizing, air-tight connections, and safety precautions to avoid damage or hazards. It also includes wiring diagrams and fuse specifications for single-phase and three-phase motors, with voltage conversion instructions for dual-voltage models.
| Recommended Fuse Rating | 15A for 1/3 HP, 20A for 1/2 HP |
|---|---|
| Pipe Suction Size | 1-1/4" for 1/3 HP, 2" for 3/4 HP |
Close the discharge valve, remove the priming plug, fill the pump with water until water flows out, replace the plug, start the pump, and slowly open the valve.
Increase pipe size from pump tapping as shown in Table I. For example, 1-1/4" for 1/3 HP, 2" for 3/4 HP.
Turn off power, remove the motor cover, turn the voltage selector dial to 115V, and reinstall the cover.