Geotech GTHDD Series Desiccant Air Dryer Operations and Maintenance Manual

This manual introduces the operation and maintenance of Geotech GTHDD Series Compressed Air Dryer


Geotech GTHDD Series Desiccant Air Dryer Operations and Maintenance Manual - cover page
Brand
Geotech
Category
Other
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
900 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
738BE66E9E02480AB94F16CD6A3F2137

About this manual

The Geotech GTHDD Series Desiccant Air Dryer utilizes the pressure swing adsorption method to dry compressed air. The system consists of two identical towers containing hygroscopic desiccant beds, controlled by a four-way solenoid valve and a solid-state timer. The process cycles every two minutes, alternating between drying and regenerating the desiccant beds to remove water vapor.

What's inside

  • Description of Operation
  • Safety Instructions
  • Specifications
  • Installation
  • Start-Up
  • Maintenance and Repair
  • Troubleshooting Guide
  • Warranty

Specifications

Maximum operating pressure120 PSIG
Inlet air temperature limit100°F
Recommended inlet filter0.01 micron coalescing filter

Frequently asked questions

What is the operating cycle time for the Geotech GTHDD dryer?

The total cycle time is 2 minutes, consisting of 60 seconds energized and 60 seconds de-energized.

What filter is required before the dryer?

A 0.01 micron coalescing filter must be installed before the dryer to remove particulates, liquid moisture, and oil.

What should be done if the dryer delivers wet air?

Check for causes such as no power, high inlet temperature, excessive air flow, low inlet pressure, dirty filters, or a plugged purge orifice.