GEFRAN KS and KS-SIL2 Series Pressure Probe Electrical Installation Manual

This document is the user manual of pressure transducer, which mainly introduces the use method, installation requirements and safety precautions of the product


GEFRAN KS and KS-SIL2 Series Pressure Probe Electrical Installation Manual - cover page
Brand
GEFRAN
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
412 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
9A32681A26D02C4B47DAEC30A35EBDD6

About this manual

This document serves as the electrical installation manual for the GEFRAN KS and KS-SIL2 series of pressure probes. It provides instructions for standard and outdoor installations, detailing electrical connections for both voltage and current amplified outputs. The guide emphasizes the use of shielded cables, proper grounding, and separation of power and signal lines to ensure safety and performance.

What's inside

  • General precautions
  • Transmitters with amplified analog output
  • Protection for outdoor installations
  • Technical specifications
  • Safety
  • Failures and troubleshooting
  • Applications

Specifications

Operating temperature range (process)-40...+125°C
Power supply (Voltage)15...30Vdc
Accuracy< ±0.5% FSO
Response time< 1 msec
Protection ratingIP65/IP67
Weight80-120 gr.

Frequently asked questions

What is the recommended cable length for the sensors?

The sensors must be powered with non-distributed networks and always at lengths of less than 30 mt.

How often should the electrical and mechanical connections be inspected?

Visual inspection of the status of the electrical and mechanical connections should be performed every two years.

What is the maximum allowed load for the current output?

The max allowed load is 2 mA.

Download PDF (412 KB)

More GEFRAN Manuals


View all GEFRAN manuals →