Gefran I3-IE-IN-IX-I7 Melt Pressure Sensor Instruction Manual

This is an instruction manual for GEFRAN I3-IE-IN-IX-I7 products, which mainly introduces the installation, use and maintenance methods of the products.


Gefran I3-IE-IN-IX-I7 Melt Pressure Sensor Instruction Manual - cover page
Brand
GEFRAN
Category
sensor
Document type
User Manual
Language
English
Pages
33
File format
PDF
File size
1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
6335FFD80A9CD58732F75CED18900893

About this manual

This instruction manual (cod. 80175D, edition 05/2014) applies to Gefran IN-I3-IX-IE series and IE-I7 performance level “c” series melt pressure sensors produced by Gefran spa. It is an integral part of the product and must always be available to operators and accompany the product, including when transferred to another user.

The document covers general information, mechanical dimensions, installation and positioning on the machine, sensor torquing, amplifier connection, wiring and calibration, electrical output connections, maintenance, and transport, storage and disposal. It also describes electronic features such as the autozero function, the autocompensation effect on IMPACT series sensors, technical specifications for each series, and the safety manual for performance level “c” sensors.

What's inside

  • General informations
  • Mechanical dimensions
  • Installation and positioning on the machine
  • Electronic features and procedures
  • Autocompensation effect on IMPACT series
  • Sensor technical specifications
  • Safety Manual for Performance Level “c” sensors

Specifications

Maximum process temperature350°C
Recommended installation torque40 Nm
Maximum cutter torque15 Nm
Dummy plug max pressure range2000 bar
Amplifier switch-on wait time60 seconds
Maximum sheath heating temperature220°C

Frequently asked questions

What is the correct temperature range for the sensors?

The correct temperature range is 350°C.

What is the recommended torque for installing the sensor?

The recommended torque is 40 Nm.

How long should you wait after switching on the sensor before operating the transducer?

Wait 60 seconds before starting to operate the transducer.

What is the maximum pressure range for dummy plugs?

The max pressure range is 2000 bar for all rods.

Download PDF (1 MB)

More GEFRAN Manuals


View all GEFRAN manuals →