This is an instruction manual for MX series oval gear flow meter, it includes operating and maintenance instructions.
This instruction manual provides detailed guidance for installing, maintaining, and operating Macnaught MX Series oval gear flowmeters. It covers setup procedures, maintenance steps including disassembly and reassembly, and technical specifications for various models. The flowmeters are designed for liquid measurement with high accuracy and repeatability across a wide range of viscosities and flow rates. Installation requires proper strainer placement, orientation, and pressure management to avoid damage. Maintenance involves careful handling of components, torque specifications, and periodic inspection of strainers and wetted parts.
| Temperature Range (MX06P - MX50P) | -40°C - 150°C |
|---|---|
| Temperature Range (MX06S - MX100S) | -40°C - 120°C |
| Accuracy (MX06 - MX100) | ±0.5% of reading |
The flowmeter uses an oval gear design where fluid passing through causes rotors to turn. One rotor has magnets that trigger a sensor to generate a pulse output related to the K-Factor.
A 74 micron / 200 mesh strainer is recommended for 1/4" meters.
Torque ratings vary by size: MX06-MX12 (6.5 Nm), MX19-MX25 (15 Nm), MX40-MX100 (33 Nm).
Output types include pulse outputs (A, I, J, K, T), local digital displays (D, E, F, G, H, M), and analogue outputs (PRA, ERA, PRM).