This is an instruction manual for MX series flowmeters.
This manual provides connection and operating instructions for the Macnaught MX series Flowmeters with Pulse outputs, specifically the 1 1/2'' Oval Gear model. It details the operating principle based on the oval rotor design, which offers high accuracy and repeatability for measuring fluid flow.
| Flow Range (Below 5 cP) | 15 to 235 LPM |
|---|---|
| Flow Range (5 to 1000 cP) | 10 to 250 LPM |
| Accuracy of Reading | ±0.5% |
| Operating Voltage (Standard) | 4.5V to 24V DC |
| Maximum Current (Standard) | 7.5mA |
Yes, the meter can be installed in any orientation as long as the meter shafts are in a horizontal plane.
It is recommended that a Y or Basket type 60 mesh strainer be installed as close as possible to the inlet side of the meter.
The cap head screws should be tightened in a diagonal sequence (e.g., 1, 5, 7, 3, etc.).