Macnaught MX Series Oval Gear Flowmeter MXL-INST Instruction Manual
This instruction manual provides detailed guidance for installing, maintaining, and operating Macnaught MX Series oval gear flowmeters. It covers setup procedures, maintenance steps including disassembly and reassembly, and technical specifications for various models. The flowmeters are designed for liquid measurement with high accuracy and repeatability across a wide range of viscosities and flow rates. Installation requires proper strainer placement, orientation, and pressure management to avoid damage. Maintenance involves careful handling of components, torque specifications, and periodic inspection of strainers and wetted parts.
Covers: Operating Principle · Installation Procedure · Maintenance Procedure · Disassembly · Reassembly · Pictorial Representation

Macnaught MX40 1 1/2'' Oval Gear Flowmeter Instruction Manual
This manual provides connection and operating instructions for the Macnaught MX series Flowmeters with Pulse outputs, specifically the 1 1/2'' Oval Gear model. It details the operating principle based on the oval rotor design, which offers high accuracy and repeatability for measuring fluid flow.
Covers: Installation Procedure · Operating Principle · Maintenance Procedure · Disassembly · Reassembly · Flowmeter Specifications
Latest Macnaught manuals
Macnaught MX Series Oval Gear Flowmeter MXL-INST Instruction Manual
User Manual 32 pages · 1.5 MB · ENUser manual for Macnaught MX Series oval gear flowmeters, covering installation, maintenance, operation, and specifications for pipe sizes 1/4" to 4".
Macnaught MX40 1 1/2'' Oval Gear Flowmeter Instruction Manual
User Manual 20 pages · 2.3 MB · ENThis instruction manual covers the installation, operation, maintenance, and troubleshooting of the Macnaught MX40 1 1/2'' Oval Gear Flowmeter.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Macnaught manuals
What is the operating principle of the flowmeter?
The flowmeter uses an oval gear design where fluid passing through causes rotors to turn. One rotor has magnets that trigger a sensor to generate a pulse output related to the K-Factor.
From: Macnaught MX Series Oval Gear Flowmeter MXL-INST Instruction Manual
What strainer size is required for a 1/4" meter?
A 74 micron / 200 mesh strainer is recommended for 1/4" meters.
From: Macnaught MX Series Oval Gear Flowmeter MXL-INST Instruction Manual
Can the flowmeter be installed in any orientation?
Yes, the meter can be installed in any orientation as long as the meter shafts are in a horizontal plane.
From: Macnaught MX40 1 1/2'' Oval Gear Flowmeter Instruction Manual
What type of strainer is recommended for installation?
It is recommended that a Y or Basket type 60 mesh strainer be installed as close as possible to the inlet side of the meter.
From: Macnaught MX40 1 1/2'' Oval Gear Flowmeter Instruction Manual