This manual describes installation, connection and operation of GFX4-IR modular power controller.
This manual provides instructions for installing and operating the GEFRAN GFX4-IR 4-zone modular power controller, designed for controlling infrared lamps and inductive loads in industrial environments. It covers electrical power supply, safety precautions, EMC compliance, installation dimensions, and connection details for inputs, outputs, and fieldbus interfaces. The controller is suitable for applications such as thermoforming, hot runners, and glass tempering furnaces. Safety warnings and technical specifications are included to ensure correct and safe operation.
| Total Controlled Power | 30KW |
|---|---|
| Outputs | 5...8 logic type |
| Auxiliary Inputs | absent |
| Fuse Holders | present |
Software version: 1.2x
It is used for the power control of single-phase and 3-phase loads, including resistive loads with high and low temperature coefficient, short wave IR lamps, or transformer primaries.
A 2-phase switch/isolator conforming to safety requisites (CE mark) must be installed up-line of the controller.