This document is Ezi-STEP Plus-R manual, which introduces the functions of Ezi-STEP Plus-R, including position table, execution, teaching and jump.
This manual explains how to use the Position Table feature in Fastech's Ezi-STEP Plus-R motion controller. It covers loading data, editing motion steps, and executing commands with various modes including Normal and Single Step. The guide also details teaching functions, jump conditions, and signal-based operations.
The Position Table allows up to 256 steps to be saved and executed in sequence. Users can edit, copy, delete, and save position data. The system supports external signal inputs for teaching and jump operations, and provides output signals for start, pass, and end of motion. Safety warnings are included to prevent improper use.
| Maximum Position Table Steps | 256 |
|---|---|
| Position Table Commands | Up to 256 for Ezi-STEP-PR, 64 for Ezi-STEP-PR-MI |
| Acceleration Time | 1 to 9,999 ms |
| Deceleration Time | 1 to 9,999 ms |
| Wait Time | 0 to 60,000 ms |
Up to 256 commands can be saved for Ezi-STEP-PR, and up to 64 for Ezi-STEP-PR-MI.
It allows users to teach motion positions either through a user program or by external input signals.
The system can jump to a specified position or table based on input signals or loop conditions.
Output signals can be set to indicate start, pass, or end of motion, with specific ranges for each function.