Fastech Ezi-STEP Plus-R Position Table User Manual

This document is Ezi-STEP Plus-R manual, which introduces the functions of Ezi-STEP Plus-R, including position table, execution, teaching and jump.


Fastech Ezi-STEP Plus-R Position Table User Manual - cover page
Brand
Fastech
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
474 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
733B9CBBCD4AF1FE6F09C3E1190D26E5

About this manual

This manual explains how to use the Position Table feature in Fastech's Ezi-STEP Plus-R motion controller. It covers loading data, editing motion steps, and executing commands with various modes including Normal and Single Step. The guide also details teaching functions, jump conditions, and signal-based operations.

The Position Table allows up to 256 steps to be saved and executed in sequence. Users can edit, copy, delete, and save position data. The system supports external signal inputs for teaching and jump operations, and provides output signals for start, pass, and end of motion. Safety warnings are included to prevent improper use.

What's inside

  • Before Getting Started
  • Windows of Position Table
  • Position Table Item
  • Execution of Position Table
  • Teaching Function
  • Input Condition Jump
  • Loop Condition Jump
  • Start/Pass/End Signal Function

Specifications

Maximum Position Table Steps256
Position Table CommandsUp to 256 for Ezi-STEP-PR, 64 for Ezi-STEP-PR-MI
Acceleration Time1 to 9,999 ms
Deceleration Time1 to 9,999 ms
Wait Time0 to 60,000 ms

Frequently asked questions

How many position table commands can be saved?

Up to 256 commands can be saved for Ezi-STEP-PR, and up to 64 for Ezi-STEP-PR-MI.

What is the purpose of the 'Teaching Function'?

It allows users to teach motion positions either through a user program or by external input signals.

How does the system handle jump conditions?

The system can jump to a specified position or table based on input signals or loop conditions.

What are the output signal functions for position table?

Output signals can be set to indicate start, pass, or end of motion, with specific ranges for each function.