Walchem EZ Series Electronic Metering Pump Instruction Manual

This is the electronic metering pump instruction manual


Walchem EZ Series Electronic Metering Pump Instruction Manual - cover page
Brand
Walchem
Category
Other
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
2.1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
7DC6FD567FC4A0F1695B1B184F5CAAD5

About this manual

The Walchem EZ Series electronic metering pumps consist of a pump unit, a drive unit, and a control unit. The drive unit is an electromagnetic solenoid that moves an armature shaft to force a PTFE-faced diaphragm into the pump head cavity, increasing pressure and forcing liquid out through discharge check valves. When the solenoid is de-energized, a spring returns the armature, pulling the diaphragm out to create a vacuum that refills the pump head from the supply tank.

This instruction manual covers the complete lifecycle of the pump, including safety precautions, model code interpretation, electrical and operating specifications, installation procedures, and operation controls. It also details maintenance tasks such as diaphragm and valve replacement, provides an exploded view with a parts guide, and includes a troubleshooting section to assist with common operational issues.

What's inside

  • Introduction
  • Safety and Caution Notes
  • Principle of Operation
  • Model Code
  • Specifications
  • Installation
  • Operation
  • Maintenance
  • Troubleshooting
  • Service Policy

Specifications

Maximum Output Capacity (B11)0.6 Gal/hr
Maximum Output Capacity (C36)6.3 Gal/hr
Frequency adjustment range0 to 360 strokes per minute
Ambient temperature range32°F to 122°F (0°C to 50°C)
Liquid temperature range (PVC)32° to 104°F (0 to 40°C)
Liquid temperature range (PP, PVDF, SS)32° to 140°F (0 to 60°C)

Frequently asked questions

What is the maximum speed of the EZ Series pump?

The pump speed is adjustable up to 360 strokes per minute.

What is the voltage rating for the EZC model with 230 V AC?

The voltage rating is 230 V AC±10%.

What is the stroke adjustment range for the EZ series pumps?

The frequency adjustment range is 0 to 360 strokes per minute.