This manual provides design details of reinforcing steel
This document serves as a design manual for reinforcing steel, outlining general design details and compliance with AASHTO Standard Specifications. It provides guidance on minimizing bar bends and hooks while maintaining clarity in bar counts across different views.
| Maximum spacing for shrinkage and temperature reinforcement | 18 inches (450 mm) |
|---|---|
| Minimum clear distance between parallel bars | 1.5 times nominal diameter |
| Maximum length for #3 and #4 bars | 30 feet (9 m) |
| Maximum length for other bar sizes | 60 feet (18 m) |
Details of reinforcing steel shall comply with the requirements of the AASHTO Standard Specifications.
It is required for sidewalks, barrier rails, concrete medians, and at Corrosive Sites for all cast-in-place concrete elements.
The clear distance shall not be less than 1.5 times the nominal diameter of the bars.