This is a SAS micropile manual, which introduces the basic structure, design parameters, construction methods and relevant precautions of micropiles.
This manual provides guidelines for designing and installing SAS Micropiles, including load capacities based on material grades and soil types. It details corrosion protection options such as single and double protection systems for temporary, semi-permanent, and permanent applications. Assembly drawings and component specifications are included for different load conditions and protection levels.
The document references standards like EN 1537 and DIN 1054 for load capacities and bond stress values, and includes tables for working loads, minimum drill hole diameters, and corrosion protection matrices based on soil corrosiveness and expected performance life.
| Working Load Capacities for S 670/800 (grade 97) bar | Bar Diameter 25 mm: 329 kN yield, 236 kN ultimate; Bar Diameter 75 mm: 2960 kN yield, 2121 kN ultimate |
|---|---|
| Minimum Drill Hole Diameter for DCP Micropile | Bar Diameter 25 mm: 65 mm without coupler, 85 mm with coupler |
| Bond Stress for Cement Grout | 5 N/mm² for serviceability limit state with grout strength > 40 N/mm² |
Working load capacities are based on 60% of the nominal ultimate tensile strength (0.60 x UTS). For example, a 25 mm bar has a yield load of 329 kN and ultimate load of 236 kN.
Minimum drill hole diameter depends on bar diameter and whether a coupler is used. For example, a 25 mm bar requires 65 mm without a coupler and 85 mm with a coupler.