This manual describes the technical data, installation instructions and use of EPIC® SENSORS flanged temperature sensors by Lapp Automaatio Oy.
This document serves as the installation and user manual for Lapp Automaatio EPIC SENSORS flanged temperature sensors, specifically models Type T-F (thermocouple) and Type W-F (resistance). The sensors are constructed according to DIN 43772 form 2F and are designed for industrial measuring applications where the thermowell can be removed and replaced during maintenance. They feature mineral insulated (MI) elements and are available with ceramic connection blocks or open wire ends.
| Measuring range (Pt100) | -200…+ 550 °C |
|---|---|
| Measuring range (TC) | -200…+ 1200 °C |
| Ambient temperature (without transmitter) | -40…+135 °C |
| Connection head material (Standard/Ex i) | Aluminum |
| Connection head material (Ex d) | Aluminum or Stainless Steel |
| Sensor element sheath (Pt100) | AISI 316L |
| Sensor element sheath (TC) | Inconel 600 or AISI 316L |
| Flange material | AISI 316L |
The standard version for Type T-F is a K-type thermocouple, and for Type W-F it is a 4-wire Pt100.
Yes, the measuring elements are mineral insulated (MI) elements which can be changed on the fly.
The sensors are available as ATEX and IECEx approved protection types Ex d and Ex i.