This document introduces the datasheet of Lapp Automaatio Oy EPIC® SENSORS WELDABLE TEMPERATURE SENSOR TYPE T-D / W-D
This document provides installation instructions and user guidance for Lapp Automaatio EPIC SENSORS weldable temperature sensors, specifically types T-D (thermocouple) and W-D (resistance). These sensors feature a neck pipe and are constructed according to DIN 43772 form 4, intended for industrial measuring applications where they are immersed into a process via a weldable thermowell.
The manual covers technical data, including materials, dimensional drawings, and specific installation procedures for standard and Ex versions. It details connection methods for Pt100 and thermocouples, tightening torques, and opening the connection head for various versions. The document also includes information on approvals, serial number labeling, and contact details for the manufacturer.
| Measuring temperature range (Pt100) | -200...+550 °C |
|---|---|
| Measuring temperature range (TC) | -200...+1200 °C |
| Ambient temperature range (without transmitter) | -40...+135 °C |
| IP rating | IP65 |
| Quality certificate | ISO 9001:2015 and ISO 14001:2015 |
| Thermowell standard | DIN 43772 form 4 |
The standard version is K-type thermocouple.
Standard materials include AISI 316L, 13CrMo44, 10CrMo910, and 16Mo3.
Yes, they are available as ATEX and IECEx approved protection type Ex d and Ex i versions.