Engler Son-Mate II Veterinary Ultrasonic Dental Scaler Instruction Manual

This manual mainly introduces the use of the Son-Mate II ultrasonic dental scaler, including installation, operation and maintenance


Engler Son-Mate II Veterinary Ultrasonic Dental Scaler Instruction Manual - cover page
Brand
Engler Engineering Corporation
Document type
User Manual
Language
English
Pages
31
File format
PDF
File size
1.4 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
3B84DF68E728728E5460477C4D7E6E75

About this manual

This manual provides detailed instructions for installing, operating, and maintaining the Engler Son-Mate II veterinary ultrasonic dental scaler. It includes safety warnings, water flow requirements, component care, and troubleshooting. The device uses ultrasonic technology to remove dental debris and is designed for professional veterinary use only. Regular maintenance of tips, stacks, and water systems is emphasized to ensure optimal performance and prevent damage.

The scaler features a digital power display, reinforced aluminum chassis, and integrated circuitry. It requires a water supply of 30–60 psi and must be disconnected when not in use to avoid warranty voidance. Components like the stack and tip must be handled carefully to prevent damage, and water filters must be cleaned regularly.

What's inside

  • READ BEFORE YOU START
  • COMPANY PROFILE
  • INTRODUCTION
  • INSTALLATION INSTRUCTIONS
  • SCALER OPERATING INSTRUCTIONS
  • SCALER MAINTENANCE
  • POLISHER INSTALLATION
  • POLISHER OPERATION
  • POLISHER MAINTENANCE: PROPHY ANGLE
  • STRAIGHT HANDPIECE MAINTENANCE

Specifications

Operating Frequency18,000 Hz
Tip Vibration Amplitude0.001 to 0.004 in. (25.4 um to 102 um)
Water Pressure Requirement30 to 60 psi (2.0 to 4.2 kg/cm2)

Frequently asked questions

What is the operating frequency of the Son-Mate II?

The circuitry converts ordinary line voltage to an operating frequency of approximately 18,000 Hz.

What water pressure is required for the Son-Mate II?

The device requires a water supply of 30–60 psi.

What happens if the ultrasonic tip touches soft tissue?

It will cause burns due to the friction of the vibration.

How often should the ultrasonic stack be replaced?

The stack should be replaced every six months to a year or as needed.